Explore step by step

Available results

  1. EWI to clipped eaves with room in roof (insulation to rafters)

    A detail for external wall insulation to deal with a potential cold bridge at eaves where new insulation to rafters meets external wall insulation. To be used where there is an existing room-in-roof or loft/roof insulation to be applied to existing rafters.

    Where there is a limited overhang at the existing eaves, an integral gutter is required to enable water run-off. The EWI is used to form a verge, which is then capped with a Stainless steel gutter.

    Target values:

    Target Roof U-Value: 0.18 W/m²K Target Wall U-Value: 0.18 W/m²K

    View detail →
  2. EWI to clipped eaves with hidden gutter

    A detail for external wall insulation to deal with potential cold bridging at eaves; where new or existing loft or roof insulation meets external wall insulation.

    Where there is a limited overhang at the existing eaves, an integral hidden gutter is required to enable water run-off; to facilitate this the EWI is brought up to form a verge, which is then capped with a stainless steel gutter.

    Target values: Psi Value: 0.0778 W/mK

    View detail →